User profiles for Matthew G. Teeter
Matthew G. TeeterWestern University Verified email at uwo.ca Cited by 2156 |
Effect of taper design on trunnionosis in metal on polyethylene total hip arthroplasty
SC Tan, MG Teeter, C Del Balso, JL Howard… - The Journal of …, 2015 - Elsevier
This study examines how taper design affects corrosion and fretting at the head trunnion
surface. All hip prostheses retrieved between 1999 and 2013 with 28 mm/+ 0 heads were …
surface. All hip prostheses retrieved between 1999 and 2013 with 28 mm/+ 0 heads were …
Trunnionosis: does head size affect fretting and corrosion in total hip arthroplasty?
C Del Balso, MG Teeter, SC Tan, JL Howard… - The Journal of …, 2016 - Elsevier
Background Wear and tribocorrosion at the modular head–neck taper interface may be a
cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation …
cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation …
Bony increased-offset reverse shoulder arthroplasty vs. metal augments in reverse shoulder arthroplasty: a prospective, randomized clinical trial with 2-year follow-up
ML Van de Kleut, X Yuan, MG Teeter… - Journal of Shoulder and …, 2022 - Elsevier
Background Reverse shoulder arthroplasty (RSA) is rapidly being adopted as the standard
procedure for a growing number of shoulder pathologies. Lateralization of the glenoid …
procedure for a growing number of shoulder pathologies. Lateralization of the glenoid …
The relationship between constitutional alignment and varus osteoarthritis of the knee
PJTK Vandekerckhove, N Matlovich, MG Teeter… - Knee Surgery, Sports …, 2017 - Springer
Purpose The role of neutral alignment in total knee arthroplasty (TKA) on short- and long-term
outcomes has become controversial. Based on the concept of constitutional varus, it has …
outcomes has become controversial. Based on the concept of constitutional varus, it has …
Tribocorrosion: ceramic and oxidized zirconium vs cobalt-chromium heads in total hip arthroplasty
…, C Del Balso, JL Howard, BA Lanting, MG Teeter - The Journal of …, 2016 - Elsevier
Background This matched-cohort study aims to compare tribocorrosion between matched
ceramic and cobalt-chromium femoral head trunnions and between matched Oxinium and …
ceramic and cobalt-chromium femoral head trunnions and between matched Oxinium and …
Comparison of contact kinematics in posterior-stabilized and cruciate-retaining total knee arthroplasty at long-term follow-up
Background There is controversy regarding the superiority of posterior-stabilizing (PS) total
knee arthroplasty (TKA) and cruciate-retaining (CR) TKA. Substantial work has made …
knee arthroplasty (TKA) and cruciate-retaining (CR) TKA. Substantial work has made …
Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty
MG Teeter, DD Naudie, RW McCalden, X Yuan… - Knee Surgery, Sports …, 2018 - Springer
Purpose To examine implant migration and articular behavior of primary total knee arthroplasty
(TKA) at 10 years after index surgery and correlate to implant alignment. Methods Thirty-…
(TKA) at 10 years after index surgery and correlate to implant alignment. Methods Thirty-…
Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners
…, SJ MacDonald, MG Teeter - Clinical Orthopaedics …, 2015 - journals.lww.com
… MD 1 ; Teeter, Matthew G. PhD 1 … Teeter MG, Naudie DD, Charron KD, Holdsworth DW.
Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision …
Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision …
Do changes in patellofemoral joint offset lead to adverse outcomes in total knee arthroplasty with patellar resurfacing? A radiographic review
…, DJ Morden, SJ MacDonald, MG Teeter… - The Journal of …, 2017 - Elsevier
Background Patellofemoral joint biomechanics contribute to anterior knee pain, instability,
and dysfunction following total knee arthroplasty (TKA). Information about specific factors …
and dysfunction following total knee arthroplasty (TKA). Information about specific factors …
Prevalence and outcomes of unexpected positive intraoperative cultures in presumed aseptic revision hip arthroplasty
…, M Shehata, JL Howard, SJ MacDonald, MG Teeter… - JBJS, 2021 - journals.lww.com
Background: The prevalence and outcomes of unexpected positive cultures (UPCs) of
specimens taken during presumed aseptic revision total hip arthroplasty (THA) are unclear. The …
specimens taken during presumed aseptic revision total hip arthroplasty (THA) are unclear. The …