Skip to main content

Main menu

  • Home
  • Content
    • Current issue
    • Past issues
    • Sections
    • Collections
  • Podcasts
  • Author Info
    • Overview for authors
    • Publication fees
    • Forms
    • Editorial policies
    • Submit a manuscript
    • Open access
  • Careers
  • Alerts
    • Email alerts
    • RSS
  • About
    • General information
    • Staff
    • Editorial Board
    • Contact
  • CMAJ JOURNALS
    • CMAJ
    • CMAJ Open
    • JAMC
    • JPN

User menu

Search

  • Advanced search
CJS
  • CMAJ JOURNALS
    • CMAJ
    • CMAJ Open
    • JAMC
    • JPN
CJS

Advanced Search

  • Home
  • Content
    • Current issue
    • Past issues
    • Sections
    • Collections
  • Podcasts
  • Author Info
    • Overview for authors
    • Publication fees
    • Forms
    • Editorial policies
    • Submit a manuscript
    • Open access
  • Careers
  • Alerts
    • Email alerts
    • RSS
  • About
    • General information
    • Staff
    • Editorial Board
    • Contact
  • Subscribe to our alerts
  • RSS feeds
  • Follow CJS on Twitter
Original Article

Trapezial arthroplasty with silicone rubber implantation for advanced osteoarthritis of the trapeziometacarpal joint of the thumb

Joy C. MacDermid, James H. Roth, Y. Raj Rampersaud and Gregory I. Bain
CAN J SURG April 01, 2003 46 (2) 103-110;
Joy C. MacDermid
*Hand and Upper Limb Centre, Clinical Research Laboratory, University of Western Ontario, London, Ont.
†School of Rehabilitation Science, McMaster University, Hamilton. Ont.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James H. Roth
*Hand and Upper Limb Centre, Clinical Research Laboratory, University of Western Ontario, London, Ont.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y. Raj Rampersaud
*Hand and Upper Limb Centre, Clinical Research Laboratory, University of Western Ontario, London, Ont.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gregory I. Bain
‡Modbury Medical Centre, Modbury, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Tables
  • Responses
  • Metrics
  • PDF
Loading

Abstract

Introduction: Arthritis in the trapeziometacarpal joint of the thumb can cause swelling and loss of motion. Treatment options include arthrodesis, replacement arthroplasty and interposition arthroplasty. Our objective in this clinical study was to determine outcomes after trapezial arthroplasty with a silicone rubber implant and the relationship between self-reported and measured outcomes.

Methods: At the Hand and Upper Limb Centre, St. Joseph’s Hospital, London, Ont., a tertiary care centre, we reviewed a series of 26 patients with advanced osteoarthritis who underwent silicone rubber trapezial arthroplasty. The follow-up averaged 6.5 years. We assessed the outcomes subjectively, and by clinical, functional and radiographic examination.

Results: Although 88% of patients reported some improvement in pain and satisfaction, when quantified the improvement was less impressive: only 5.7 (on a visual analogue scale of 1–10, poor–excellent) for pain and 5.6 for satisfaction. Superior subjective results were reported by patients older than 60 years. Osteoarthritic changes had caused pronounced functional impairment in the hands of patients who underwent surgery and those who did not, so that any long-term benefit of surgery was not measurable. Patients had difficulty manipulating both small and large objects on the Jebsen’s hand function test. Peri-implant and carpal radiographic lytic changes were observed in 90% of patients. Six patients (20%) required revision surgery (3 early, 3 late), including 1 with a pathologic scaphoid fracture.

Conclusions: Although clinical, functional and radiographic results were poor, they did not predict either satisfaction or pain improvement reported by patients, illustrating the need for a comprehensive standardized outcome evaluation to make informed decisions on the value of surgical intervention for osteoarthritis of the trapeziometacarpal joint.

Positioning of the thumb away from the palm through movement at the trapeziometacarpal joint is critical to hand function. Arthritis can affect the trapezium, the surrounding carpal bones and first metacarpal, resulting in pain, swelling and loss of motion of the basal thumb joint. Typical radiographic changes in osteoarthritis (OA) of the basal joint include joint narrowing, subchondral condensation of bone, osteophyte formation and radial and proximal subluxation of the first metacarpal. This typically progresses, leading to instability, crepitation and deformity.1,2 Options for surgical treatment include arthrodesis,3 replacement arthroplasty4 and interposition arthroplasty.5

Silicone rubber trapezial arthroplasty was pioneered by Swanson,1,4 who reported good long-term results in pain relief and patient satisfaction. In long-term follow-up of 150 cases, Swanson and colleagues2 reported that patients, who were primarily female with OA, could perform 80% of their activities of daily living (ADL) with minimal pain. Strength was higher than preoperative values, and 78% of patients had improved ability to perform ADL.2 Although this positive outlook was supported by others, 6–12 concerns have increased over time regarding the complications of silicone arthroplasty. Significant complications that occur after silicone arthroplasty include instability, deformation, implant failure and silicone synovitis. The most serious concerns with silicone rubber trapezial arthroplasty are the high incidence of implant instability and silicone synovitis.7–15

The literature on silicone rubber trapezial arthroplasty suggests these complications may lead to reduced function in patients with increased usage over time. Previous case series have focused on the prevalence of complications and radiographic changes. We were interested to know 1) if the prevalence of complications was similar in our patients and 2) whether patients’ self-report of pain relief and satisfaction reflected the objective outcomes with this procedure.

Method

Patients

A clinical and radiographic review was performed on patients who underwent a silicone rubber trapezial arthroplasty performed by a single hand surgeon (J.H.R.), between 1983 and 1992. The indication for surgery was disabling pain due to primary OA of the trapeziometacarpal joint that was unresponsive to nonoperative management. Thirty-six patients with a minimum follow-up of 12 months were eligible for the study. Three patients died, 3 patients could not be reviewed because they were medically unwell, 1 had emigrated, 2 refused and 2 were lost to follow-up. Twenty-five patients (30 implants) were reviewed, representing 76% of the surviving population.

Self-reported effectiveness

Subjective evaluation included a 5-item questionnaire with a visual analogue scale (VAS). The patients were asked to compare the current status of their hand to their preoperative status with respect to pain, hand and wrist movement, strength, ability to perform ADL and overall satisfaction. The options ranged from completely worse (left end), to no change (centre) to completely better (right end). The position marked on the VAS was converted to a percentage change score. Pilot testing of the questionnaire reliability indicated that it was very high.

Objective measures of effectiveness

Objective clinical assessment included examination of the wrist and thumb for swelling, tenderness and range of motion (ROM). Clinical stability was studied for evidence of subluxation or dislocation. Grip strength was measured with the JAMAR dynamometer (Sammons Pre ston, Bolingbrook, Ill.) (position 2) according to standardized methods.16 Tip and key pinch were measured with a B and L pinch strength meter (Instron, Canton, Mass.).17 The Purdue pegboard18 and Jebsen’s test of hand function19 were evaluated according to previously described methods. Scores from these tests were compared with published normative values, stratified on the basis of age and hand dominance.

Standard posteroanterior and lateral radiographs of both wrists were obtained with the thumb in abduction. These were reviewed independently of the surgeon (J.H.R.) and clinical information. Each radiograph was assessed for the following:

  • Prosthetic wear was assessed by measuring the relative height of the ulnar versus radial borders of the prosthesis (Fig. 1).13

  • Prosthetic position with respect to the distal pole of the scaphoid was measured in millimetres from the radial border of the scaphoid to the ulnar border of the prosthesis (Fig. 2). Subluxation was defined as less than 80% articulation.9

  • Osseous changes were evaluated in the thumb metacarpal, scaphoid and carpus according to the grading system developed by Creighton and associates.7

  • Radiographs of the contralateral wrist were also assessed for evidence of osteoarthritis.

FIG. 1
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 1

This diagram shows prosthetic wear. Percent prosthetic wear is measured by comparing the ulnar border (a) to the radial border (b) of the prosthesis.

FIG. 2
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 2

Position of the prosthesis with respect to the distal pole of the scaphoid is measured as percentage subluxation by dividing the amount of prosthesis–scaphoid articulation in millimetres (c) by the width of the prosthesis (d).

Statistical analysis

Tests of difference between operated and nonoperated hands were performed using paired t-tests. Tests between subgroups (age) were performed using a standard independent samples t-test. The Pearson correlation coefficient was used as the measure of association. All statistical analyses were performed in Sigma-Stat (SPSS Science) (α = 0.05).

Surgical technique

The surgical technique was similar to that reported by Sotereanos and colleagues.11 The procedure was performed under tourniquet control with 3.5× loupe magnification. A dorsoradial longitudinal incision was centred over the trapeziometacarpal joint, and the superficial radial nerve and radial artery were identified and protected. The first extensor compartment was released and the abductor pollicis longus (APL) muscle divided. A capsulotomy was then made and the trapezium was excised en bloc. The base of the thumb metacarpal was resected perpendicular to the shaft and the intramedullary canal reamed to accept the implant stem. A trial prosthesis was inserted and assessed for seating. If the prosthesis tended to subluxate, an appropriate portion of the trapezoid bone was excised. A Swanson high performance, silicone rubber trapezial implant was then inserted into the intramedullary canal. Two absorbable Vicryl sutures were passed through the implant and into the flexor carpi radialis muscle, in the ulnar volar aspect of the wound. The prosthesis was assessed for stability and the thumb for ROM. The capsule was imbricated and the abductor pollicis longus reattached and plicated to reinforce the repair. All but 7 of the 30 thumbs had a metacarpophalangeal joint fusion, stabilized with a temporary percutaneous Kirschner wire at 30° of flexion. A below-elbow bulky dressing was applied with the thumb in abduction. After 1 week, a thumb spica cast was applied and worn for 5 weeks. Six weeks after the operation if there was radiographic evidence of metacarpophalangeal joint fusion, the Kirschner wire was removed. Hand therapy was begun, and the patients were allowed to return to ADL. Hand therapy consisted of gradual strengthening and functional activity. Home programs were typically used.

Results

Patient characteristics are reported in Table 1. Average follow-up was 6.5 years (median 6.6), with 50% of the patients being tested between 3 and 10 years after operation. Contralateral osteoarthritis was noted in 80% of the patients.

View this table:
  • View inline
  • View popup
Table 1

Characteristics of 25 Patients (30 Hands) Who Underwent Trapezial Silicone Rubber Arthroplasty

Eighty-eight percent of patients reported some pain improvement and 75% were satisfied. Patients rated the average amount of improvement in pain as 5.7/10, and their satisfaction as 5.6/10. The least improvement was reported in strength (Table 2). Superior subjective results were noted in patients more than 60 years of age (Fig. 3). A statistically significant greater improvement in strength, ADL and patient satisfaction (p = 0.004) was present in patients who were more than 60 years of age at the time of their operation. A similar trend toward greater improvement in patients more than 60 years old was observed in all other subjective categories.

FIG. 3
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 3

The effect of age at the time of surgery. Subjective results in patients younger than 60 years (black columns) are compared with those of patients older than 60 years at the time of surgery (white columns) (*p < 0.05).

View this table:
  • View inline
  • View popup
Table 2

Subjective Results of Silicone Rubber Trapezial Arthroplasty in 25 Patients*

Nine hands (30%) had tenderness or swelling at the base of the thumb. ROM of the wrist and thumb of the operated and nonoperated hands was not significantly different (Table 3). Forty-eight percent of patients had clinical instability of the prosthesis. Only 6 of these had tenderness or swelling at the base of the thumb. The prosthesis could be subluxated in 9 patients and dislocated in 5. The average tip pinch was significantly weaker on the operated side compared with the nonoperated side (p < 0.05). A similar trend with nonsignificant differences was noted for grip strength and key pinch.

View this table:
  • View inline
  • View popup
Table 3

Hand Strength and Thumb Range of Movement (ROM) in 25 Patients (30 Hands) Who Underwent Trapezial Arthroplasty

Compared to normative values, both hands performed poorly in standardized functional testing with the Jebsen’s hand function and Purdue pegboard tests (Fig. 4). Functional deficits were most pronounced in the manipulation of large objects. Significantly (p < 0.02) more time was required for the operative hand to manipulate large objects compared with the unoperated side. This was most pronounced in patients with subluxation. However, patients also had difficulty manipulating small objects compared to normative values on Jebsen’s hand (56% greater time) and Purdue pegboard (71% fewer assemblies completed) tests.

FIG. 4
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 4

Results of the Jebsen hand function test. This diagram shows the percentage impairment of function in nonoperated hands (black columns) compared with operated hands (white columns) with normal levels from age- and sex-matched patients in the subtests of writing, turning cards, handling small objects, feeding and manipulating large, light and large, heavy weights (*statistically different from the nonoperated hand, p < 0.05).

Using the grading system described by Creighton and associates,7 90% of the patients had radiographic lytic changes. Radiographic changes were seen in 64% of the metacarpals. All but 1 were grade C lytic changes (Fig. 5). Scaphoid changes were seen in 59% of patients, and 50% of these were grade 4 changes. Changes in other carpal bones were noted in 58% of patients. Pancarpal changes were found in 1 patient. Sixty-five percent of patients had greater than 20% radial displacement of the prosthesis. Dislocation was found in 10%. Prosthetic wear averaged 15%, with a range of 0%–70%. Wear was found to be moderately correlated with radiographic lytic changes (r = 0.52). Three prostheses were fractured at the base of the thumb, and 1 of these was associated with a pathologic fracture of the scaphoid (Fig. 6).

FIG. 5
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 5

Posteroanterior view of a wrist with a Swanson HP silicone rubber trapezial implant 6 years after surgery. There are extensive lytic changes in the thumb metacarpal and the scaphoid. The prosthesis is severely worn and fractured.

FIG. 6
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG. 6

This radiograph demonstrates a fractured prosthesis and a pathologic scaphoid fracture in a patient 9 years after implantation. This patient presented with significant pain and tenderness at the base of the thumb.

One patient had reflex sympathetic dystrophy, which resolved after hand therapy. Six patients had their implant removed. Three were removed early after operation, 1 because of a staphylococcal infection, 1 for a symptomatic prosthetic dislocation and 1 for symptomatic silicone synovitis 5 months after insertion. Three symptomatic fractured prostheses were removed after 6, 9 and 10 years respectively. The patient with a 9-year follow-up also had a pathologic scaphoid fracture. This represents a 20% overall revision surgery rate (10% early, 10% late).

With the exception of the checkers subtest of Jebsen’s hand function test, functional, radiographic and objective tests results were not significant predictors of patients’ satisfaction (Table 4). Longer follow-up was associated with a poorer outcome. There were high correlations among the 5 subjective ratings made by patients (p < 0.01).

View this table:
  • View inline
  • View popup
Table 4

Predictors of Patient Satisfaction After Silicone Rubber Trapezial Arthroplasty

Discussion

This study determined that patients with silicone rubber trapezial arthroplasty reviewed in long-term follow-up can be expected to have significant impairment and disability, which can be attributed to ongoing destructive disease as well as complications of silicone arthroplasty. These findings are in agreement with previous work. However, this study demonstrates that patients’ perceptions of surgical success are not related to the severity of their impairment or to their complications. Patients’ perception of surgical success must be related to factors not evaluated in this study. Others have found that factors related to efficient operation of the clinic are important predictors of patient satisfaction, at least in the short-term.20

One consequence of the lack of correlation between patient satisfaction and physical symptomatology may be that patients with significant complications resulting from silicone synovitis might not request surgical re-evaluation. Since removal of the implant is advisable in cases of silicone synovitis to minimize continued pathologic bone destruction, physicians should be thinking about surveillance for the effects of silicone synovitis.

In this study, we found that 88% of patients reported some pain improvement following silicone trapezial arthroplasty. This would appear to be an excellent result and is comparable to results reported by others.1,2,4,6–13 Previous studies have tended to rely on examiner ratings, which most typically rate patients as improved or unimproved. Whereas 88% of our patients reported improvement in pain, the average improvement was only 5.7 out of 10, indicating that pain relief was quite incomplete. The fact that the overall percentage of patients reporting some pain relief was very high, whereas average pain improvement was moderate, illustrates the importance of standardized quantitative pain measures. Reliance on simple yes or no evaluations may not provide adequate insight into treatment response.

An inherent weakness of any follow-up study is the lack of consistent quantitative measurement of preoperative status. Therefore, the subjective rating scale used in the present study required that subjects compare their follow-up status to their preoperative status and rate the overall change. Although one might question the patients’ ability to accurately recall their preoperative status, patient perception of pain relief over time is an important concept in itself. Prospective studies are required to ensure unbiased information on pain relief. Future prospective outcome studies on thumb arthritis and its management should include a validated pain scale as a primary outcome measure.

Patient satisfaction correlated significantly with the extent of pain relief. Patient satisfaction reflects a variety of elements, including patients’ perceptions of efficacy in relation to their needs and expectations, as well as nontreatment issues such as the pleasantness of the physical surroundings and support staff. The high correlation between subjective perceptions of change in physical status and pain, and overall patient satisfaction may be related to 2 issues. First, it reflects the importance of pain relief to the patient and supports the current practice of using pain as an indication for surgery. Second, retrospective assessments of change in physical status may be affected by overall patient satisfaction.

This study demonstrated better subjective results in patients over 60 years of age. Amadio and DeSilva6 also reported better subjective results in men more than 60 years of age. We found significantly greater “improvement” in patient-rated ADL in patients older than 60 years at the time of surgery. This supports the assumption that higher satisfaction in this older age group is related to lower physical demand.

Some authors1,2,8–10,12 have reported good functional results after silicone rubber trapezial arthroplasty. Most of these studies have not reported the results from standardized functional testing. We found that patients reported an average improvement in their ability to perform their ADL of 43%. However, we also observed that patients had considerable objective functional deficits, and these tended to be worse on the operated side. Patients had marked difficulty manipulating objects that required wide abduction of the thumb on their operated side. This was a problem particularly in patients who had subluxation. Patients also had difficulties with tasks involving small objects and a significantly weaker tip pinch. There was no statistically significant correlation between the patient rating of improvement or overall satisfaction and these functional test results. This emphasizes the importance of not relying solely on self-report measures when judging the efficacy of surgical interventions.

This group of patients had poor function bilaterally, indicating that their disability was to a large extent a result of the arthritic process itself. It appears that many patients perceived the surgery as having had some positive effect on their functional ability, despite the similarity in impairment on their nonoperated hand and their ongoing functional limitations. The extent to which treatment alters patient function is difficult to ascertain in OA given the progressive bilateral nature of the disease process, which can vary between hands. Large prospective studies are required to determine if the course of deterioration is altered by surgical intervention.

Forty-eight percent of patients demonstrated clinical instability of the prosthesis. This is consistent with reports of up to 83% incidence of prosthetic instability. However, our study demonstrated that there was no significant correlation between the presence of instability and subjective, objective or radiologic results. The lack of correlation between patient ratings and objective findings suggests that one “outcome” cannot be predicted from the other.

Prosthetic wear and cold flow commonly occurs on the ulnar border of the prosthesis.10 We found an average of 15% prosthetic wear. Prosthetic wear was found to correlate moderately (r = 0.52) with radiographic cystic changes. Freeman and Honner8 also found a similar correlation. Although host response is unpredictable, it has been shown to be related to the load of microparticulate debris, which in turn is directly proportional to prosthetic wear.21

In the literature, lytic radiographic changes have been reported in 0–90% of patients.1,2,7–15,21–27 Several authors have reported that these changes are progressive.1,2,12,14,15,26 We found that 90% of our patients demonstrated radiographic evidence of silicone synovitis, with an average 6.5-year follow-up. Peimer and colleagues21 reported that silicone synovitis can result in pathologic fractures of carpus or trapezium. They suggested that these fractures were the end-stage of untreated particulate synovitis. In our series, one patient had a pathological scaphoid fracture. However, computed tomography demonstrated extensive cystic changes throughout the entire scaphoid and the other carpal bones, which were grossly underestimated on plain radiographs. This would tend to support the hypothesis of Peimer and colleagues.

In 1986, Pelligrini and Burton10 reported a 16% surgical revision rate at 3 years. More recently, Freeman and Honner8 reported late revisions in 7% of the patients reviewed. We had 3 (10%) early revisions and another 3 patients (10%) who required late revision, at an average follow-up of 8.3 years. One patient had a pathologic scaphoid fracture, and all 3 patients requiring late revision had a fractured prosthesis and postoperative histopathologic findings of silicone synovitis.

The life expectancy in a 60-year-old woman is 24 years and in a man is 19 years.28 Therefore, we are concerned that the longer term usage required for even elderly patients would result in significant impairments, which worsens with time. It is possible that over time a significant number of patients will suffer pathologic fractures, pancarpal disease or other complications requiring revision surgery. Perhaps owing to the recognition of complications with silicone rubber procedures, a number of alternative procedures have gained popularity. For example, at our centre, tendon interposition arthroplasty is most commonly performed. It should be noted that these newer procedures have not been subjected to large randomized trials or cohort studies, so only grade 3 and 4 level evidence exists to guide current surgical practice.29

Conclusions

The natural history of OA of the trapeziometacarpal joint is progression toward pronounced functional difficulties as evidenced by the severity of deficits demonstrated in the nonoperated hands of patients in this study. The findings of this study agree with those of other studies1,2,8,10,12 that report a high percentage of patients with pain improvement and satisfaction after silicone rubber trapezial arthroplasty. However, these findings may have overestimated the true extent of pain relief, owing to a lack of quantified objective measurements of pain. Whereas a high percentage of patients in this study experienced some relief, the amount of pain relief was not satisfactory.

Our study demonstrated that clinical, functional and radiographic abnormalities are common 6.5 years after operation. Quantitative patient ratings of outcome in terms of pain relief, movement, strength, ADL and overall satisfaction were not correlated with objective clinical or radiographic measures, indicating that patient perceptions of outcome provide an important, but different, perspective of outcome, one that can augment but not replace valid physical impairment measures. Although this study showed superior subjective results in patients more than 60 years old, the value of this procedure when preferable options are available must be questioned. This opinion is based on the high incidence of revision surgery, the risk of pathologic fracture, the unknown true long-term results, the increasing life expectancy of our population28 and the existence of alternative soft-tissue procedures,5 which have more stable outcomes and fewer long-term complications. A better understanding of surgical outcomes for advanced arthritis of the basal joint of the thumb requires, at least, a long-term prospective outcome study of more recently favoured procedures (i.e., tendon interpositional arthroplasty) and, ideally, randomized trials of alternative options.

Acknowledgements

Dr. MacDermid is a career scientist of the Ontario Ministry of Health and Long-Term Care, Health Research Personnel Development Program. This study was funded by a Rea Foundation Grant from the Arcangalo Rea Family Foundation.

Footnotes

  • Competing interests: None declared.

  • Accepted November 5, 2002.

References

  1. ↵
    1. Swanson AB
    . Disabling arthritis at the base of the thumb. J Bone Joint Surg Am 1972;54:456–70.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    1. Swanson AB,
    2. deGoot Swanson G,
    3. Watermeier JJ
    . Trapezium implant arthroplasty: long-term evaluation of 150 cases. J Hand Surg Am 1981;6:125–41.
    OpenUrlCrossRef
  3. ↵
    1. Bamberger HB,
    2. Stern PJ,
    3. Kiefhaber TR,
    4. Mc-Donough JJ,
    5. Cantor RM
    . Trapeziometacarpal joint arthodesis: a functional evaluation. J Hand Surg Am 1992;17:605–11.
    OpenUrlCrossRef
  4. ↵
    1. Swanson AB
    . Silicone rubber implants for replacement of arthritic or destroyed joints in the hand. Surg Clin North Am 1968; 48:1113–27.
    OpenUrlPubMed
  5. ↵
    1. Burton RI,
    2. Pellegrini VD Jr.
    . Surgical management of basal joint arthritis of the thumb: part II. Ligament reconstruction with tendon interposition arthroplasty. J Hand Surg Am 1999;11:324–32.
    OpenUrl
  6. ↵
    1. Amadio PC,
    2. DeSilva SP
    . Comparison of the results of trapeziometacarpal arthrodesis in men with osteoarthritis of the trapeziometacarpal joint. Ann Chir Main Memb Super 1990;9:358–63.
    OpenUrlCrossRefPubMed
  7. ↵
    1. Creighton JJ,
    2. Steichen JB,
    3. Strickland JW
    . Long-term evaluation of Silastic trapezial arthroplasty in patients with osteoarthritis. J Hand Surg Am 1991;16:510–9.
    OpenUrlCrossRef
  8. ↵
    1. Freeman GR,
    2. Honner R
    . Silastic replacement of the trapezium. J Hand Surg Br 1992;17:458–62.
    OpenUrlPubMed
  9. ↵
    1. Hofammann DY,
    2. Ferlic DC,
    3. Clayton ML
    . Arthroplasty of the basal joint of the thumb using a silicone prosthesis. Long-term follow-up. J Bone Joint Surg Am 1987;69:993–7.
    OpenUrlAbstract/FREE Full Text
  10. ↵
    1. Pellegrini VD Jr.,
    2. Burton RI
    . Surgical management of basal joint arthritis of the thumb. Part 1. Long-term results of silicone implant arthroplasty. J Hand Surg Am 1986;11:309–24.
    OpenUrlCrossRef
  11. ↵
    1. Sotereanos DG,
    2. Taras J,
    3. Urbaniak JR
    . Niebauer trapeziometacarpal arthroplasty: a long-term follow-up. J Hand Surg Am 1993;18:560–4.
    OpenUrlCrossRef
  12. ↵
    1. Sollerman C,
    2. Herrlin K,
    3. Abrahamsson SO,
    4. Lindholm A
    . Silastic replacement of the trapezium for arthrosis — a twelve year follow-up study. J Hand Surg Br 1988;13:426–9.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Pellegrini VD Jr.
    . Osteoarthritis at the base of the thumb. Orthop Clin North Am 1992;23:83–102.
    OpenUrlPubMed
  14. ↵
    1. Khoo CT
    . Silicone synovitis — the current role of silicone elastomer implants in joint reconstruction. J Hand Surg Br 1993;18: 679–86.
    OpenUrlPubMed
  15. ↵
    1. Peimer CA
    . Long-term complications of trapeziometacarpal silicone arthroplasty. Clin Orth Rel Res 1987;220:86–96.
    OpenUrlPubMed
  16. ↵
    1. Fess EE
    . Grip strength. In: Casanova JS, editor. Clinical assessment recommendations. 2nd ed. Chicago: American Society of Hand Therapists; 1992. p. 41–6.
  17. ↵
    1. Mathiowetz V,
    2. Weber K,
    3. Volland G,
    4. Kashman N
    . Reliability and validity of grip and pinch strength evaluations. J Hand Surg Am 1984;9:222–6.
    OpenUrlCrossRefPubMed
  18. ↵
    1. Tiffin J,
    2. Asher EJ
    . The Purdue Pegboard: norms and studies of reliability and validity. J Appl Psych 1948;32:234–47.
    OpenUrlCrossRef
  19. ↵
    1. Jebsen RH,
    2. Taylor N,
    3. Trieschmann RB,
    4. Trotter MJ,
    5. Howard LA
    . An objective and standardized test of hand function. Arch Phys Med Rehabil 1969;50:311–9.
    OpenUrlPubMed
  20. ↵
    1. Eaton RG
    . Replacement of the trapezium for arthritis of the basal articulations: a new technique with stabilization by tenodesis. J Bone Joint Surg Am 1979;61:76–82.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    1. Peimer CA,
    2. Taleisnik FS,
    3. Sherwin MA
    . Pathologic fractures: a complication of microparticulate synovitis. J Hand Surg Am 1991;16:835–43.
    OpenUrl
    1. Aptekar RC,
    2. Davie JM,
    3. Cattell HS
    . Foreign body reaction to silicone rubber: complication of a finger joint implant. Clin Orthop 1974;98:231–2.
    OpenUrlCrossRefPubMed
    1. Chrisitie AJ,
    2. Weinberger KA,
    3. Dietrich M
    . Silicone lymphadenopathy and synovitis. JAMA 1977;237:1463–4.
    OpenUrlCrossRefPubMed
    1. Worsing RA Jr.,
    2. Engber WD,
    3. Lange TA
    . Reactive synovitis from particulate silastic. J Bone Joint Surg Am 1982;64:581–5.
    OpenUrlAbstract/FREE Full Text
    1. Peimer CA,
    2. Medige J,
    3. Echert BS,
    4. Wright CS,
    5. Howard BS
    . Reactive synovitis after silicone arthroplasty. J Hand Surg Am 1986;11:624–38.
    OpenUrlCrossRef
  22. ↵
    1. Atkinson RE,
    2. Smith RJ
    . Silicone synovitis following silicone implant arthroplasty. Hand Clin 1986;2:291–9.
    OpenUrlPubMed
  23. ↵
    1. Randell T
    . Surgeons grapple with synovitis, fractures around silicone implants for the hand and wrist. JAMA 1992;268:13–8.
    OpenUrlCrossRefPubMed
  24. ↵
    1. Nair C,
    2. Karim R
    . An overview of health care systems: Canada and selected OECD countries. Health Rep 1993;5:259–79.
    OpenUrlPubMed
  25. ↵
    1. Griffith GM,
    2. Griffith A,
    3. Weiland AJ,
    4. Hotchkiss RN,
    5. McCormack RR
    . Ligament interposition basal joint arthroplasty without tendon interposition. Clin Orthop 1997;342:42–5.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Canadian Journal of Surgery: 46 (2)
CAN J SURG
Vol. 46, Issue 2
1 Apr 2003
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author

Article tools

Respond to this article
Print
Download PDF
Article Alerts
To sign up for email alerts or to access your current email alerts, enter your email address below:
Email Article

Thank you for your interest in spreading the word on CJS.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Trapezial arthroplasty with silicone rubber implantation for advanced osteoarthritis of the trapeziometacarpal joint of the thumb
(Your Name) has sent you a message from CJS
(Your Name) thought you would like to see the CJS web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Trapezial arthroplasty with silicone rubber implantation for advanced osteoarthritis of the trapeziometacarpal joint of the thumb
Joy C. MacDermid, James H. Roth, Y. Raj Rampersaud, Gregory I. Bain
CAN J SURG Apr 2003, 46 (2) 103-110;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
‍ Request Permissions
Share
Trapezial arthroplasty with silicone rubber implantation for advanced osteoarthritis of the trapeziometacarpal joint of the thumb
Joy C. MacDermid, James H. Roth, Y. Raj Rampersaud, Gregory I. Bain
CAN J SURG Apr 2003, 46 (2) 103-110;
Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

Similar Articles

Collections

  • Arthroplasty

Content

  • Current issue
  • Past issues
  • Collections
  • Alerts
  • RSS

Authors & Reviewers

  • Overview for Authors
  • Publication Fees
  • Forms
  • Editorial Policies
  • Submit a manuscript

About

  • General Information
  • Staff
  • Editorial Board
  • Contact Us
  • Advertising
  • Reprints
  • Copyright and Permissions
  • Accessibility
  • CMA Civility Standards
CMAJ Group

Copyright 2022, CMA Impact Inc. or its licensors. All rights reserved. ISSN 2291-0026

All editorial matter in CJS represents the opinions of the authors and not necessarily those of the Canadian Medical Association or its subsidiaries.

To receive any of these resources in an accessible format, please contact us at CMAJ Group, 500-1410 Blair Towers Place, Ottawa ON, K1J 9B9; p: 1-888-855-2555; e: [email protected].

View CMA's Accessibility policy.

Powered by HighWire