PT - JOURNAL ARTICLE AU - Kyu-Hwan Jung AU - Suk-Bae Moon TI - Cephalic vein cutdown for totally implantable central venous port in children: a retrospective analysis of prospectively collected data AID - 10.1503/cjs.025512 DP - 2014 Feb 01 TA - Canadian Journal of Surgery PG - 21--25 VI - 57 IP - 1 4099 - http://canjsurg.ca/content/57/1/21.short 4100 - http://canjsurg.ca/content/57/1/21.full SO - CAN J SURG2014 Feb 01; 57 AB - Background: The jugular vein cutdown for a totally implantable central venous port (TICVP) has 2 disadvantages: 2 separate incisions are needed and the risk for multiple vein occlusions. We sought to evaluate the feasibility of a cephalic vein (CV) cutdown in children.Methods: We prospectively followed patients who underwent a venous cutdown for implantation of a TICVP between Jan. 1, 2002, and Dec. 31, 2006. For patients younger than 8 months, an external jugular vein cutdown was initially tried without attempting a CV cutdown. For patients older than 8 months, a CV cutdown was tried initially. We recorded information on age, weight, outcome of the CV cutdown and complications.Results: During the study period, 143 patients underwent a venous cutdown for implantation of a TICVP: 25 younger and 118 older than 8 months. The CV cutdown was successful in 73 of 118 trials. The 25th percentile and median body weight for 73 successful cases were 15.4 kg and 28.3 kg, respectively. There was a significant difference in the success rate using the criterion of 15 kg as the cutoff. The overall complication rate was 8.2%.Conclusion: The CV cutdown was an acceptable procedure for TICVP in children. It could be preferentially considered for patients weighing more than 15 kg who require TICVP.