Table 3

GRADE evidence summarizing the effectiveness of chest tubes placed to suction or water seal: positive values favour water seal, negative values favour suction

OutcomeNo. studiesNo. participantsResults (95% CI)Quality of the evidence
Duration of air leak, d2175WMD 1.15 (−0.64 to 2.94)Very low*
Duration of air leak/length of staple line, d/cm2175WMD 0.07 (0.01 to 0.13)§Very low*
Incidence of prolonged air leak7814ARR 0.04 (−0.01 to 0.09)Low*
Duration of chest tube, d4404WMD 0.96 (−0.12 to 2.05)Low*
Duration of hospital stay, d4404WMD 2.19 (−0.63 to 5.01)Low*
Incidence of pneumothorax4292ARR −0.14 (−0.21 to −0.07)§Moderate
Incidence of arrhythmia2236ARR −0.04 (−0.15 to 0.08)Very low*
Incidence of death2191ARR −0.01 (−0.04 to 0.03)Low
Incidence of pneumonia2236ARR −0.03 (−0.12 to 0.06)Very low*
  • ARR = absolute risk reduction; CI = confidence interval; WMD = weighted mean difference.

  • * Evidence limited by heterogeneity between studies.

  • Evidence limited by imprecise data (small sample size or event rate).

  • Evidence limited by high or unclear risk of bias in studies.

  • § Statistically significant.