Table 1

Biomechanical properties of locked versus unlocked construct

Biomechanical parameterConstruct, mean (SD)p value
LockedUnlocked
Stiffness, Nm/°649.4267.40.32
Energy to failure, J7 945.37 619.20.76
Torque to failure, Mm20 471.314 141.80.83
Angle to failure, °43.915.20.81
  • SD = standard deviation.