Abstract
A 10-year retrospective audit. (1) The incidence of infection; (2) causative organisms; (3) whether eradication of infection is achievable with spinal implant retention; (4) patient outcome. The reported incidence of infection following posterior spinal instrumentation is between 2.6 and 3.8%. Management of infection is controversial, with some advocating serial wound debridement while others report that infection cannot be eradicated with retention of implants. There are no published data demonstrating that propionibacteria are associated with early postoperative infection. The management of infected cases at our institution includes eventual removal of their implants. Our population was identified by studying the case notes of all patients who had undergone removal of spinal implants and cross-referencing this population with positive microbiology or histology reports. The incidence of infection was 3.7%. Propionibacteria were isolated in 45% of cases. The diagnosis of infection was unexpected in 25% of patients, following removal of implants for prominence of implants or back pain. Sixty per cent of patients with acute postoperative deep wound infection had continuing active infection on subsequent removal of implants, despite long-term antibiotics and wound debridement. Fourty-six per cent of patients had a stable, pain-free spine at the end of their treatment. This is the largest reported series of infections following posterior spinal instrumented fusions of which we are aware. Propionibacteria are a common cause of infection and successful eradication of infection cannot be reliably achieved with antibiotics and wound debridement alone.
Similar content being viewed by others
Change history
20 July 2017
An erratum to this article has been published.
References
Atkins BL, Athanasou N, Deeks JL et al (1998) Prospective evaluation of criteria for microbiological diagnosis of prosthetic joint infection at revision arthroplasty. J Clin Microbiol 36(10):2932–2939
Ben-Galim P, Giladi M, Schwartz D, Ashkenazi E, Millgram M, Dekel S, Floman Y (2006) Association between sciatica and microbial infection: true infection or culture contamination? Spine 31(21):2507–2509
Chu R, Tummala R, Hall W (2001) Focal intracranial infections due to propionibacterium acnes: report of three cases. Neurosurgery 49(3):717–720
Clark C, Shufflebarger H (1999) Late-developing infection in instrumented idiopathic scoliosis. Spine 24(18):1909–1916
Clayton JJ, Baig W, Reynolds GW, Sandoe JAT (2006) Endocarditis caused by propionibacterium species: a report of three cases and a review of clinical features and diagnostic difficulties. J Med Microbiol 55:981–987
Cook S, Asher M, Lai S et al (2000) Reoperation after primary posterior instrumentation and fusion for idiopathic scoliosis: toward defining late operative site pain of unknown cause. Spine 25(4):463–468
Deckey JE, Court C, Bradford DS (2000) Loss of sagittal plane correction after removal of spinal implants. Spine 25(19):2453–2460
Gaine WJ, Andrew S, Chadwick P et al (2001) Late operative site pain with Isola posterior instrumentation requiring implant removal: infection or metal reaction? Spine 26(5):538–587
Glassman SD, Dimar JR, Puno RM et al (1996) Salvage of instrumented lumbar fusions complicated by surgical wound infection. Spine 21(18):2163–2169
Hahn F, Zbinden R, Min K (2005) Late implant infections caused by propionibacterium acnes in scoliosis surgery. Eur Spine J 14(8):783–788
Kowalski TJ, Berbari EF, Huddleston PM, Steckelberg JM, Mandrekar JN, Osmon DR (2007) The management and outcome of spinal implant infections: contemporary retrospective cohort study. Clin Infect Dis 44:913–20
Levi AD, Dickman CA, Sonntag VK (1997) Management of postoperative infection after spinal instrumentation. J Neurosurg 86:975–980
Muschik M, Luck W, Schlenzka D (2004) Implant removal for late-developing infection after instrumented posterior spinal fusion for scoliosis: re-instrumentation reduces loss of correction. A retrospective analysis of 45 cases. Eur Spine J 13(7):645–651
Perry JW, Montgomerie JZ, Swank S, Gilmore DS, Maeder K (1997) Wound infections following spinal fusion with posterior segmental spinal instrumentation. Clin Infect Dis 24:558–661
Richards BS (1995) Delayed infections following posterior spinal instrumentation for the treatment of idiopathic scoliosis. J Bone Joint Surg Am 77-A(4):524–529
Schofferman L, Zucherman J, Schofferman J et al (1991) Diptheroids and associated infections as a cause of failed instrument stabilization procedures in the lumbar spine. Spine 16(3):356–358
Sponseller P, LaPorte DM, Hungerford MW et al (2000) Deep wound infections after neuromuscular scoliosis surgery: a multicenter study of risk factors and treatment outcomes. Spine 25(19):2461–2466
Theiss SM, Lonstein J, Winter R (1996) Wound infections in reconstructive spine surgery. Orthop Clin North Am 27(1):105–110
Viola R, King H, Adler S et al (1997) Delayed infection after elective spinal instrumentation and fusion: a retrospective analysis of eight cases. Spine 22(20):2444–2450
Weinstein MA, McCabe JP, Cammisa FP (2000) Postoperative spinal wound infection: a review of 2,391 consecutive index procedures. J Spinal Disord Tech 13(5):422–426
Wild A, Pinto MR, Butler L et al (2003) Removal of lumbar instrumentation for the treatment of recurrent low back pain in the absence of pseudoarthrosis. Arch Orthop Trauma Surg 123(8):414–418
Author information
Authors and Affiliations
Corresponding author
Additional information
An erratum to this article is available at https://doi.org/10.1007/s00586-017-5216-2.
Rights and permissions
About this article
Cite this article
Collins, I., Wilson-MacDonald, J., Chami, G. et al. The diagnosis and management of infection following instrumented spinal fusion. Eur Spine J 17, 445–450 (2008). https://doi.org/10.1007/s00586-007-0559-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-007-0559-8