Background: The major challenge in the management of patients with an infected open abdomen (OA) is to control septic peritonitis and intra-abdominal fluid secretion, and to facilitate repeated abdominal exploration, while preserving the fascia for delayed primary closure. We here present a novel method for closure of the infected OA, based on continuous dynamic tension, in order to achieve re-approximation of the fascial edges of the abdominal wall.
Methods: Eighteen cases with severe peritonitis of various origin (e.g., gastrointestinal perforations, anastomotic leakage) were primarily stabilized by laparostomy, sealed with either the vacuum-assisted closure abdominal dressing or the Bogotá bag. After hemodynamic stabilization and control of the sepsis, the Abdominal Re-approximation Anchor System (ABRA; Canica Design, Almonte, Ontario, Canada) was applied. This system approximates the wound margins through dynamic traction exerted by transfascial elastomers. Before ABRA application, 5/18 patients had a grade 2B, 2/18 a grade 3, and 11/18 a grade or 4 status according to the open abdomen classification of Björck.
Results: In this severely ill population the mean time before ABRA system application was 12 days (range: 2-39 days). Two of 18 patients died of non-ABRA-related causes within three weeks. In 14 of the remaining 16 patients (88%) primary abdominal closure of the midline was accomplished in 15 days (range: 7-30 days). The other two patients needed a component separation technique according to Ramirez to reach closure. However, secondary wound dehiscence occurred in both these patients. Two thirds of patients (12/18) developed pressure sores to the skin and/or dermis, but all healed without further complications. During outpatient clinic follow-up, 4/14 successfully closed patients still developed a midline hernia.
Conclusions: Delayed primary closure of OA in septic patients could be achieved in 88% with this new approximation system. However, the risk of hernia development remained. We consider this system a useful tool in the treatment of septic patients with an open abdomen.