Fine needle aspiration cytology of thyroid gland diseases

Acta Cytol. 1990 Mar-Apr;34(2):251-6.

Abstract

From 1982 to 1987, 2,433 lesions of the thyroid gland in 1,796 patients were examined by fine needle aspiration (FNA). Cytopathology classified 66.91% of the aspirates as benign, 10.76% as thyroiditis, 4.89% as suspected (unspecified) neoplasia, 1.31% as positive for malignancy and 16.11% (392) as unsatisfactory. The histologic diagnoses in 257 cases were compared with cytologic diagnoses to determine the accuracy of FNA cytology of thyroid lesions, yielding a sensitivity of 71.43%, a specificity of 100% and an accuracy of 95.09%. This data strongly supports thyroid FNA as an important preoperative diagnostic tool. Follicular carcinomas were difficult to cytologically differentiate from nonmalignant follicular neoplasms, and papillary thyroid carcinomas less than 2 cm in diameter in elderly patients were frequently misdiagnosed or diagnosed only as "suspect lesion."

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle
  • Cytodiagnosis
  • Female
  • Goiter / pathology
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Thyroid Diseases / pathology*
  • Thyroid Neoplasms / pathology*
  • Thyroiditis / pathology