A quarter of a century of experience with aortic valve-sparing operations

J Thorac Cardiovasc Surg. 2014 Sep;148(3):872-9; discussion 879-80. doi: 10.1016/j.jtcvs.2014.04.048. Epub 2014 May 15.

Abstract

Objective: To examine the late outcomes of aortic valve-sparing operations to treat patients with aortic root aneurysm with and without aortic insufficiency (AI) in a cohort of patients followed up prospectively since 1988.

Methods: A total of 371 consecutive patients had undergone aortic valve-sparing surgery (mean age, 47 ± 15 years; 78% men) from 1988 through 2010. In addition to the aortic root aneurysm, 47% had moderate or severe AI, 35.5% had Marfan syndrome, 12.1% had type A aortic dissection, 9.2% had bicuspid aortic valve, 8.4% had mitral insufficiency, 16.1% had aortic arch aneurysm, and 10.2% had coronary artery disease. Reimplantation of the aortic valve was used in 296 patients and remodeling of the aortic root in 75. Cusp repair by plication of the free margin along the nodule of Arantius was used in 36.6% of patients, and reinforcement of the free margin with a double layer of fine Gore-Tex suture in 24.2%. The patients were followed up prospectively with images of the aortic root for a median follow-up of 8.9 ± 5.2 years.

Results: A total of 4 operative and 39 late deaths occurred. Survival at 18 years was 76.8% ± 4.31%, lower than that for the general population matched for age and gender. Age, type A aortic dissection, impaired ventricular function, and preoperative AI were associated with increased mortality on multivariable analysis. Reoperations on the aortic valve were performed in 8 patients for recurrent AI and in 2 for infective endocarditis. Freedom from reoperation on the aortic valve at 18 years was 94.8% ± 2.0%. No predictors of the need for reoperation were found on multivariable analysis. Eighteen patients developed AI greater than mild. Freedom from AI greater than mild at 18 years was 78.0% ± 4.8%. No predictors of recurrent AI were identified on multivariable analysis.

Conclusions: Aortic valve-sparing operations continue to provide excellent clinical outcomes, although a slow but progressive deterioration of aortic valve function seems to occur during the first 2 decades of follow-up. Preoperative AI and cusp repair had no adverse effect on valve function.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aortic Aneurysm / diagnosis
  • Aortic Aneurysm / etiology
  • Aortic Aneurysm / mortality
  • Aortic Aneurysm / physiopathology
  • Aortic Aneurysm / surgery*
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / diagnosis
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / mortality
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Insufficiency / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / mortality
  • Cardiac Surgical Procedures / adverse effects
  • Cardiac Surgical Procedures / methods*
  • Cardiac Surgical Procedures / mortality
  • Cardiac Valve Annuloplasty
  • Child
  • Female
  • Hospital Mortality
  • Humans
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Postoperative Complications / mortality
  • Postoperative Complications / surgery
  • Prospective Studies
  • Reoperation
  • Replantation
  • Risk Factors
  • Suture Techniques
  • Time Factors
  • Treatment Outcome
  • Young Adult