Acute rupture of the descending thoracic aorta: repair with use of endovascular stent-grafts

J Vasc Interv Radiol. 1997 May-Jun;8(3):337-42. doi: 10.1016/s1051-0443(97)70568-2.

Abstract

Purpose: To describe the use of endovascular stent-grafts to treat acute ruptures of the descending thoracic aorta as an alternative to surgery in high-risk patients.

Materials and methods: From July 1992 to August 1996, 95 patients underwent stent-grafting of the descending thoracic aorta for a variety of lesions. Of these, 11 patients with acute (< or = 7 days) rupture from aneurysms (n = 8) or trauma (n = 3) underwent repair with use of endovascular stent-grafts. Rupture was confirmed with preoperative imaging studies and occurred in the mediastinum (n = 9), the pleural space (n = 1), or the lung (n = 1). All patients were considered high surgical risk due to generalized cardiopulmonary disease and/or previous thoracotomies. Stent-grafts were constructed from Z stents covered with polyester fabric and delivered through a catheter under fluoroscopic control from a remote access site.

Results: Stent-graft deployment was successful in all patients. There were no complications of perigraft leak, stent migration, paraplegia, or intraoperative death. Two patients died in the follow-up period: one of ventricular perforation during unrelated thoracic surgery for tumor resection (day 1) and one of cardiac arrest (day 28). All others are alive (mean follow-up, 15.1 months).

Conclusion: For acute rupture of the thoracic aorta, endovascular stent-graft repair is technically feasible and may be a therapeutic alternative to a surgical interposition graft in patients considered high risk for conventional thoracotomy. Long-term studies are necessary to determine the role of stent-grafts in preventing future aortic rupture.

MeSH terms

  • Acute Disease
  • Aorta, Thoracic / injuries
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Rupture / diagnostic imaging
  • Aortic Rupture / surgery*
  • Blood Vessel Prosthesis*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Risk Factors
  • Rupture
  • Stents*
  • Time Factors
  • Tomography, X-Ray Computed