Static and dynamic load on hip contact of hip prosthesis and Thai femoral bones

K Chalernpon, P Aroonjarattham… - … of Mechanical and …, 2015 - publications.waset.org
Total hip replacement had been one of the most successful operations in hip arthritis
surgery. The purpose of this research had been to develop a dynamic hip contact of Thai …

Efforts to improve cementless femoral stems in THR: 2-to 5-year follow-up of a high-offset femoral stem with distal stem modification (Secur-Fit Plus)

SJ Incavo, T Havener, E Benson, BJ McGrory… - The Journal of …, 2004 - Elsevier
A retrospective review of 81 sequential primary total hip arthroplasties using a cementless,
high-offset femoral stem was performed. Follow-up was 24 to 60 months. The average age …

The effect of physiological load configuration on interface micromotion in cementless femoral stems

MRA Kadir, UN Hanserr - Jurnal Mekanikal, 2007 - jurnalmekanikal.utm.my
The most commonly reported failure modes of cementless hip stems are loosening and thigh
pain; both are attributed to the relative motion at the bone-implant interface due to failure to …

[PDF][PDF] Polyetheretherketon (PEEK)-II. část: Poznatky o využití v klinické praxi

D Pokorný, P Fulín, M Šlouf, D Jahoda, I Landor… - ACHOT, 2010 - achot.actavia.cz
Polyetheretherketone (PEEK) is one of the up-to-date organic polymer thermoplastics with
applications in orthopaedics and trauma medicine. This study presents a detailed analysis of …

Artroplastía total de cadera con vástago no cementado.

FJ Cruz Vázquez… - Acta Ortopédica …, 2006 - search.ebscohost.com
Una de las prótesis totales de cadera no cementadas que han sido más ampliamente
utilizadas es la AML (Anatomic Medullary Locking), la cual es una prótesis que tiene una …

The Effect of Implant Design on Stability

MR Abdul Kadir, MR Abdul Kadir - Computational Biomechanics of the Hip …, 2014 - Springer
This chapter analysed the effect of implant design on primary stability. Three different
categories were formed from a collection of cementless hip stem designs—straight …

Total hip arthroplasty with cementless stem.

FJC Vázquez, AV Leija - Acta Ortopédica Mexicana, 2006 - medigraphic.com
One of the most frequently used cementless hip prostheses is the AML (Anatomic Medullary
Locking) device, a prosthesis with a predominantly diaphyseal fixation, porous coating …

Postoperative Computertomographie zementfreier Hüftprothesenschäfte

F Martini, U Leichtle, C Lebherz… - RöFo-Fortschritte auf …, 2003 - thieme-connect.com
Ziel: Darstellung der Wertigkeit postoperativer Computertomographien (CT) zur
Lockerungsdiagnostik zementfreier Hüftprothesenschäfte. Material und Methode …

[PDF][PDF] Artroplastía total de cadera con vástago no cementado

FJC Vázquez, AV Leija - Acta Ortopédica Mexicana, 2006 - medigraphic.com
Una de las prótesis totales de cadera no cementadas que han sido más ampliamente
utilizadas es la AML (Anatomic Medullary Locking), la cual es una prótesis que tiene una …

[CITATION][C] Biomechanical Effect of Fin on Hip Prosthesis to Thai Femoral Bone

B Pradabkaew, P Aroonjarattham, N Saktaveekulkit… - stress, 2011